Correlative light-electron microscopy
Correlative light-electron microscopy (CLEM) is the combination of an optical microscope - usually a fluorescence microscope - with an electron microscope. In an integrated CLEM system, the sample is imaged using an electron beam and an optical light path simultaneously. Traditionally, samples would be imaged using two separate microscopy modalities, potentially at different facilities and using different sample preparation methods. Integrated CLEM is thus considered to be beneficial because the methodology is quicker and easier, and it reduces the chance of changes in the sample during the process of data collection. Overlay of the two images is thus performed automatically as a result of the integration of two microscopes.[1]
This technique is used in order to obtain information at different length scales: the electron microscope provides high-resolution information down to the nano-scale, while the fluorescence microscope highlights the regions of interest. CLEM is used for various disciplines in the life sciences, including neuroscience, tissue research, and protein research.
Correlative microscopy is much more than simply a combination of microscopes, but also of software, techniques and data.
Fluorescence microscope[]
In preparation for imaging with a fluorescence microscope, different methods can be used, such as fluorophores or dyes, immunolabeling, and genetically encoded fluorescent proteins. Different fluorescent labels can be used in order to highlight multiple regions of interest in the sample.[2] Recently Kumar et al [3] combined FRET based molecular tension measurements[4] with cryo-electron microscopy to study how force on talin (a focal adhesion protein which directly links integrins to actin) is related to actin organization. Regions of high talin tension have highly aligned and linear filamentous actin while regions of low tension have less well-aligned actin structure.[3]
Electron microscope[]
The electron microscope is used to obtain structural information at the nano-scale. Unlike an optical microscope, an electron microscope is able to surpass the diffraction limit of light. This is because the wavelength of accelerated electrons is much shorter than the wavelength of visible light.[5]
References[]
- ^ BV, DELMIC. "Automated Overlay - Technical Note | DELMIC". request.delmic.com. Retrieved 2017-02-08.
- ^ "What is Correlative Light and Electron Microscopy?". 2018-04-25.
- ^ a b Kumar, Abhishek; Anderson, Karen L.; Swift, Mark F.; Hanein, Dorit; Volkmann, Niels; Schwartz, Martin A. (September 2018). "Local Tension on Talin in Focal Adhesions Correlates with F-Actin Alignment at the Nanometer Scale". Biophysical Journal. 115 (8): 1569–1579. Bibcode:2018BpJ...115.1569K. doi:10.1016/j.bpj.2018.08.045. ISSN 0006-3495. PMC 6372196. PMID 30274833.
- ^ Kumar, Abhishek; Ouyang, Mingxing; Dries, Koen Van den; McGhee, Ewan James; Tanaka, Keiichiro; Anderson, Marie D.; Groisman, Alexander; Goult, Benjamin T.; Anderson, Kurt I. (2016-05-09). "Talin tension sensor reveals novel features of focal adhesion force transmission and mechanosensitivity". J Cell Biol. 213 (3): 371–383. doi:10.1083/jcb.201510012. ISSN 0021-9525. PMC 4862330. PMID 27161398.
- ^ Voortman, Lenard (2014). "Integration without compromise". Microscopy Today. 22 (6): 30–35. doi:10.1017/S1551929514001199. S2CID 138111672.
Further reading[]
- Sueters - Di Meo, Josey; Liv, Nalan; Hoogenboom, Jacob P. (2016). "Using Advanced Correlative Microscopy to Study Complex Biological Samples". Encyclopedia of Analytical Chemistry. pp. 1–31. doi:10.1002/9780470027318.a9473. ISBN 9780470027318.
- Zonnevylle, A.C.; Van Tol, R.F.C.; Liv, N.; Narvaez, A.C.; Effting, A.P.J.; Kruit, P.; Hoogenboom, J.P. (2013). "Integration of a high-NA light microscope in a scanning electron microscope". Journal of Microscopy. 252 (1): 58–70. doi:10.1111/jmi.12071. ISSN 0022-2720. PMID 23889193.
- Electron microscopy